| dc.description.abstract | Se exploró la posibilidad de utilizar la morfología del registro de onda de pulso radial obtenida mediante un transductor de movimiento para evaluar la velocidad de propagación aórtica. Se efectuó el registro de onda de pulso en arteria radial mediante un transductor apoyado sobre la zona de palpación del pulso, sobre un conjunto de 167 voluntarios varones sanos normotensos de edades comprendidas entre la 2a y la 7a década. Se identificó en los registros la onda reflejada y se definió un coeficiente de velocidad como el cociente entre la talla del individuo y el tiempo transcurrido entre el máximo de la onda sistólica y el instante de llegada de dicha onda. Se halló que en los normotensos el coeficiente mencionado aumentó en forma lineal con la edad, en una proporción similar al aumento de velocidad de propagación aórtica medido con otros métodos. Se repitió el procedimiento en otro conjunto de 125 varones hipertensos sin otros factores de riesgo, de edades entre la 3a y la 7a década, hallándose valores similares a los normotensos solamente en la 3a década, a partir de la cual se registró un incremento significativo de dicho índice. Tales hallazgos sustentan la factibilidad de utilizar tal tipo de registros para evaluar indirectamente la velocidad de propagación junto con el índice de aumentación, un parámetro habitualmente utilizado en el análisis de onda de pulso. | es_AR |
| dc.description.abstract | ABSTRACT: Velocity estimation of aortic propagation based on radial pulse wave analysis. We analyzed the possibility of using the radial pulse wave morphology, obtained by a movement transducer, to evaluate the aortic pulse wave velocity. The radial pulse wave signals were obtained by using a transducer, located on the pulse palpation area, in 167 healthy normotensive male volunteers, ages 20 to 70. The reflected wave was identified in every case. Also, a speed coefficient was defined as the ratio between the individual’s height and the time between the maximum systolic wave and the arrival time of the reflected wave. We found that the specified coefficient in normotensive individuals increased linearly with age, in a similar way to the increase in aortic propagation velocity measured by other methods. The procedure was repeated on another set of 125 individuals with hypertension, without other risk factors, aged between the 3rd and 7th decade. This time we found similar values to normotensive individuals only on the 3th decade, and a pronounced increase on the velocity coefficient at advanced ages was observed. These findings support the feasibility of using this type of signals to indirectly evaluate the propagation velocity together with the increase index, a parameter commonly used in pulse wave analysis. | en |
| dc.format | application/pdf | es_AR |
| dc.language.iso | spa | es_AR |
| dc.publisher | Fundación Revista Medicina | es_AR |
| dc.rights | info:eu-repo/semantics/openAccess | es_AR |
| dc.subject | velocidad de propagación aórtica | es_AR |
| dc.subject | tonometría | es_AR |
| dc.subject | onda de pulso radial | es_AR |
| dc.subject | aortic wave velocity | en |
| dc.subject | tonometry | en |
| dc.subject | radial pulse wave | en |
| dc.title | Estimación de la velocidad de propagación aortica basada en el análisis de la onda de pulso radial | es_AR |
| dc.type | Article | es_AR |
| dc.rights.holder | https://creativecommons.org/licenses/by/4.0/ | es_AR |
| dc.type.oa | info:eu-repo/semantics/bachelorThesis | es_AR |
| dc.type.snrd | info:ar-repo/semantics/tesis de grado | es_AR |
| dc.type.info | info:eu-repo/semantics/publishedVersion | es_AR |
| dc.description.fil | Fil: Clara, Fernando. Universidad Nacional de Mar del Plata. Facultad de Ingeniería. Laboratorio de Bioingeniería, Argentina | es_AR |
| dc.description.fil | Fil: Meschino, Gustavo Javier. Universidad Nacional de Mar del Plata. Facultad de Ingeniería. Laboratorio de Bioingeniería, Argentina | es_AR |
| dc.description.fil | Fil: Scandurra, Adriana Gabriela. Universidad Nacional de Mar del Plata. Facultad de Ingeniería. Laboratorio de Bioingeniería, Argentina | es_AR |
| dc.description.fil | Fil: Blanco, Gustavo. Instituto de Clínica Médica. Clínica 25 de Mayo, Mar del Plata, Argentina | es_AR |
| dc.description.fil | Fil: Casarini, Alfredo. Instituto de Clínica Médica. Clínica 25 de Mayo, Mar del Plata, Argentina | es_AR |
| dc.description.fil | Fil: Corral, Pablo. Instituto de Clínica Médica. Clínica 25 de Mayo, Mar del Plata, Argentina | es_AR |
| dc.journal.volume | 71 | es_AR |
| dc.journal.number | 3 | es_AR |
| dc.journal.pagination | 231-237 | es_AR |
| dc.journal.pais | Argentina | es_AR |
| dc.journal.ciudad | Buenos Aires | es_AR |
| dc.journal.title | Medicina | es_AR |